TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Mouse Adiponectin ELISA Kit
Sunlong Medical™ Mouse Adiponectin ELISA Kit
ADIPOQ elisa kit | adiponectin elisa kit | C1Q and collagen domain containing elisa kit | Acdc | Acrp30 | Ad | adipo | adipocyte complement related protein | adipocyte | C1Q and collagen domain containing | adiponectin | apM1 | APN | GBP28
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

SAMPLE TYPE Serum, plasma, cell culture supernatant, and other biological samples
SAMPLE VOLUME 10 μL
SENSITIVITY 0.73 pg/mL
RANGE 31.25 pg/mL – 2000 pg/mL
ASSAY TIME 3.5 h
RECOVERY 92% – 113%
AVERAGE RECOVERY 1.07
INTRA PRECISION 5.1% – 8.8%
INTER-PRECISION 7.3% – 7.7%
PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-Adiponectin/Acrp30 monoclonal antibody
Mouse Adiponectin/Acrp30 freeze-dried standard
Adiponectin/Acrp30 detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-mouse Adiponectin antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, Adiponectin present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing to remove unbound substances, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of Adiponectin in the samples. A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

Partial purchase records(bought amounts latest17)

UsernameQuantitybought time
Fe***22024-08-15
Ma***32024-07-23
Um***22024-07-14
Ol***22024-07-05
Na***12024-07-01
Total 17 records, divided into4 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.