TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Human β-NGF ELISA Kit
Sunlong Medical™ Human β-NGF ELISA Kit
NGF elisa kit | nerve growth factor elisa kit | beta-nerve growth factor | Beta-NGF | HSAN5 | MGC161426 | MGC161428 | nerve growth factor beta polypeptide | nerve growth factor | beta polypeptide | nerve growth factor | beta subunit | NGFB | pro-nerve g
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Cat NO.:
EL0226Hu
Product:
Sunlong Medical™ Human β-NGF ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
85% - 115%
Mean Spike Recovery:
0.98
CV of Intra plate:
3.0 % - 7.0 %
CV of Inter plate:
3.0 % - 7.9 %
NCBI_Gene:
4803
UniProtKB:
P01138

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-β-NGFA monoclonal antibody
Human β-NGFA freeze-dried standard
β-NGFA detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-human β-NGF antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, β-NGF present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing to remove unbound substances, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of β-NGF in the samples.A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

References (0)

No References

Bought notes(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.