TEL: +86 571 56623320    EMAIL: SALES@SUNLONGBIOTECH.COM

Sunlong Medical™ Human Thrombopoietin/TPO ELISA Kit
Sunlong Medical™ Human Thrombopoietin/TPO ELISA Kit
Thrombopoietin Elisa kit | TPO ELISA Kit
Total
(Vip priceV)
Regular members: $455.2

Details

Citations

Cat NO.:
EL0215Hu
Product:
Sunlong Medical™ Human Thrombopoietin/TPO ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
72% - 124%
Mean Spike Recovery:
0.97
CV of Intra plate:
2.6 % - 6.4 %
CV of Inter plate:
2.3 % - 5.4 %
NCBI_Gene:
Inquiry
UniProtKB:
Inquiry

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-Thrombopoietin/TPO monoclonal antibody
Human Thrombopoietin/TPO freeze-dried standard
Thrombopoietin/TPO detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-human TPO antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, TPO present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing to remove unbound substances, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of TPO in the samples.A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

Cat NO.:
EL0215Hu
Product:
Sunlong Medical™ Human Thrombopoietin/TPO ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
72% - 124%
Mean Spike Recovery:
0.97
CV of Intra plate:
2.6 % - 6.4 %
CV of Inter plate:
2.3 % - 5.4 %
NCBI_Gene:
Inquiry
UniProtKB:
Inquiry

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-Thrombopoietin/TPO monoclonal antibody
Human Thrombopoietin/TPO freeze-dried standard
Thrombopoietin/TPO detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-human TPO antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, TPO present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing to remove unbound substances, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of TPO in the samples.A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

 1. Identification of Plasma Thrombopoietin Level and Its Significance in Patients with Aplastic Anemia and Myelodysplastic Syndrome

Global Medical Genetics 2023-07-28

Partial purchase records(bought amounts latest7)

UsernameQuantitybought time
Ol***12024-08-30
Ab***32024-08-18
Ka***32024-08-01
Ma***22024-06-22
Ow***22024-06-05
Total 7 records, divided into2 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.
Swipe right to complete verification
Please waiting...