TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Human CEACAM1/CD66a ELISA Kit
Sunlong Medical™ Human CEACAM1/CD66a ELISA Kit
CEACAM1 elisa kit | CEA cell adhesion molecule 1 elisa kit | antigen CD66 | BGP | BGP-1 | BGP1 | BGPI | biliary glycoprotein 1 | biliary glycoprotein adhesion molecule | carcinoembryonic antigen related cell adhesion molecule 1 | carcinoembryonic antigen-
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Cat NO.:
EL0137Hu
Product:
Sunlong Medical™ Human CEACAM1/CD66a ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
81% - 117%
Mean Spike Recovery:
0.97
CV of Intra plate:
3.8 % - 4.8 %
CV of Inter plate:
3.2 % - 4.3 %
NCBI_Gene:
634
UniProtKB:
P13688
PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-CEACAM1/CD66a monoclonal antibody
Human CEACAM1/CD66a freeze-dried standard
Human CEACAM1/CD66a detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-human CEACAM1 antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and the detection antibody labeled with horseradish peroxidase are added to the wells of the ELISA plate. After incubation, CEACAM1 present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of CEACAM1 in the samples. A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

  

 

References (0)

No References

Bought notes(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.