TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Mouse Dkk-1 ELISA Kit
Sunlong Medical™ Mouse Dkk-1 ELISA Kit
DKK1 elisa kit | dickkopf WNT signaling pathway inhibitor 1 elisa kit | mdkk-1
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Cat NO.:
EL0099Mo
Product:
Sunlong Medical™ Mouse Dkk-1 ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
80% - 118%
Mean Spike Recovery:
0.01
CV of Intra plate:
2.7 % - 4.2 %
CV of Inter plate:
2.5 % - 4.2 %
NCBI_Gene:
13380
UniProtKB:
O54908

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-Dkk-1 monoclonal antibody
Mouse Dkk-1 freeze-dried standard
Dkk-1 detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-mouse Dkk-1 antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, Dkk-1 present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing to remove unbound substances, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of Dkk-1 in the samples.A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

Partial purchase records(bought amounts latest20)

UsernameQuantitybought time
Ra***32024-08-22
Mi***32024-08-12
Ra***12024-08-04
Ga***32024-07-31
Ab***12024-07-25
Total 20 records, divided into4 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.