TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Human P4HB ELISA Kit
Sunlong Medical™ Human P4HB ELISA Kit
P4HB elisa kit | prolyl 4-hydroxylase subunit beta elisa kit | cellular thyroid hormone-binding protein | CLCRP1 | collagen prolyl 4-hydroxylase beta | DSI | ERBA2L | GIT | glutathione-insulin transhydrogenase | P4Hbeta | p55 | PDI | PDIA1 | PHDB | PO4DB
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Cat NO.:
EL0067Hu
Product:
Sunlong Medical™ Human P4HB ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
77% - 104%
Mean Spike Recovery:
0.93
CV of Intra plate:
2.5 % - 3.9 %
CV of Inter plate:
1.6 % - 6.2 %
NCBI_Gene:
5034
UniProtKB:
P07237
PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-P4HB monoclonal antibody
Human P4HB freeze-dried standard
Human P4HB detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-human P4HB antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and the detection antibody labeled with horseradish peroxidase are added to the wells of the ELISA plate. After incubation, P4HB present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of P4HB in the samples. A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

Partial purchase records(bought amounts latest13)

UsernameQuantitybought time
Na***12024-09-03
Ja***12024-07-30
Zo***32024-07-14
Mi***12024-06-01
Be***32024-05-24
Total 13 records, divided into3 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.