TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Mouse CCL20/MIP-3α ELISA Kit
Sunlong Medical™ Mouse CCL20/MIP-3α ELISA Kit
CCL20 elisa kit | C-C motif chemokine ligand 20 elisa kit | CKb4 | exodus-1 | MIP-3[a] | MIP-3A | MIP3A | Scya20 | small inducible cytokine subfamily A20 | ST38
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Cat NO.:
EL0064Mo
Product:
Sunlong Medical™ Mouse CCL20/MIP-3α ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
82% - 96%
Mean Spike Recovery:
0.9
CV of Intra plate:
4.5 % - 7.5 %
CV of Inter plate:
5.6 % - 6.9 %
NCBI_Gene:
20297
UniProtKB:
O89093

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-CCL20/MIP-3α monoclonal antibody
Mouse CCL20/MIP-3α freeze-dried standard
CCL20/MIP-3α detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA) technique. Monoclonal antibodies specific for mouse CCL20 are pre-coated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, the CCL20 present in the sample binds to the solid-phase antibody and the detection antibody. After washing to remove unbound substances, streptavidin-HRP is added. After washing again, the TMB chromogenic substrate is added and color development is carried out while avoiding light. The intensity of the color reaction is directly proportional to the concentration of CCL20 in the sample. A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

References (0)

No References

Bought notes(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.