TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Mouse E-Cadherin ELISA Kit
Sunlong Medical™ Mouse E-Cadherin ELISA Kit
CDH1 elisa kit | cadherin 1 elisa kit | AA960649 | E-cad | E-cadherin | Ecad | expressed sequence AA960649 | L-CAM | Um | UM | uvomorulin
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Cat NO.:
EL0044Mo
Product:
Sunlong Medical™ Mouse E-Cadherin ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
95% - 110%
Mean Spike Recovery:
0.99
CV of Intra plate:
3.0 % - 4.8 %
CV of Inter plate:
3.4 % - 4.8 %
NCBI_Gene:
12550
UniProtKB:
P09803

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-E-Cadherin monoclonal antibody
Mouse E-Cadherin freeze-dried standard
Mouse E-Cadherin detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-mouse E-Cadherin antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, E-Cadherin present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing to remove unbound substances, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of E-Cadherin in the samples.A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

Partial purchase records(bought amounts latest21)

UsernameQuantitybought time
Bo***12024-08-30
Um***22024-07-09
Ca***12024-07-07
Ga***32024-06-26
Za***22024-05-31
Total 21 records, divided into5 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.