TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Human sVCAM-1/CD106 ELISA Kit
Sunlong Medical™ Human sVCAM-1/CD106 ELISA Kit
VCAM1 elisa kit | vascular cell adhesion molecule 1 elisa kit | CD106 | CD106 antigen | DKFZp779G2333 | INCAM-100 | MGC99561 | vascular cell adhesion protein 1
Total
(Vip priceV)
Regular members: $455.2
  • Save more [Favourable] 20% Discount for new kits
  • NO.:EL0040Hu
    Species:Human
    Assay range:31.25pg/mL-2000pg/mL
    Sensitivity:2.65 pg/mL
    Sample Volume:100 μL Pre-diluted sample
    Assay type:Sandwich Method
    Validity:Two Years
  • Goods click count:208
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
View History [Clear]

Details

Citations

Cat NO.:
EL0040Hu
Product:
Sunlong Medical™ Human sVCAM-1/CD106 ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
86% - 111%
Mean Spike Recovery:
0.99
CV of Intra plate:
4.4 % - 7.0 %
CV of Inter plate:
2.3 % - 4.5 %
NCBI_Gene:
7412
UniProtKB:
P19320

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-sVCAM-1/CD106 monoclonal antibody
Human sVCAM-1/CD106 freeze-dried standard
sVCAM-1/CD106 detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-human sVCAM-1 antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, sVCAM-1 present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing to remove unbound substances, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of sVCAM-1 in the samples.A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

1. ATP-citrate lyase controls endothelial gluco-lipogenic metabolism and vascular inflammation in sepsis-associated organ injury

Cell Death & Disease 2023-07-06
 
PHYTOCHEMISTRY 2023-03-07
 
IUBMB LIFE 2023-08-19

Partial purchase records(bought amounts latest5)

UsernameQuantitybought time
Ga***12024-05-17
Bo***32024-05-01
Um***22024-04-11
Za***22024-03-23
Di***32024-02-13
Total 5 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.