TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Human C-Reactive Protein ELISA Kit
Sunlong Medical™ Human C-Reactive Protein ELISA Kit
CRP elisa kit | C-reactive protein elisa kit | C-reactive protein | pentraxin-related | c-reactive protein | petaxin related | MGC149895 | MGC88244 | pentraxin 1 | PTX1
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Citations

Cat NO.:
EL0036Hu
Product:
Sunlong Medical™ Human C-Reactive Protein ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
93% - 107%
Mean Spike Recovery:
1
CV of Intra plate:
3.0 % - 5.8 %
CV of Inter plate:
2.9 % - 5.5 %
NCBI_Gene:
1401
UniProtKB:
P02741

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti- CRP monoclonal antibody
Human CRP freeze-dried standard
CRP detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-human CRP antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, CRP present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing to remove unbound substances, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of CRP in the samples. A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

1. BMI-specific inflammatory response to phthalate exposure in early pregnancy: findings from the TMCHESC study

ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH 2023-11-20
 
JOURNAL OF ULTRASOUND IN MEDICINE 2023-03-07

Partial purchase records(bought amounts latest13)

UsernameQuantitybought time
Pe***12024-08-19
Al***22024-08-19
Um***32024-07-02
Ta***12024-06-30
Br***22024-06-26
Total 13 records, divided into3 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.