TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Mouse IL-17A High Sensitivity ELISA Kit
Sunlong Medical™ Mouse IL-17A High Sensitivity ELISA Kit
IL17A elisa kit | interleukin 17A elisa kit | Ctla-8 | Ctla8 | cytotoxic T lymphocyte-associated protein 8 | IL-17A | Il17 | interleukin 17
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Cat NO.:
HS-EL0077Mo
Product:
Sunlong Medical™ Mouse IL-17A ELISA KitHigh Sensitivity ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
82% - 120%
Mean Spike Recovery:
1.05
CV of Intra plate:
4.1% – 4.9%
CV of Inter plate:
4.8% – 9.7%
NCBI_Gene:
16171
UniProtKB:
Q62386

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-IL-17A monoclonal antibody
Mouse IL-17A freeze-dried standard
IL-17A detect Antibody
Standard Diluent
HRP-labeled streptavidin
Signal enhancer concentrate
Signal enhancer diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-mouse IL-17A antibodies are precoated on a high-affinity ELISA plate.Standards and test samples are added to the wells of the ELISA plate. After incubation, the IL-17A present in the samples binds to the solid-phase antibodies. After washing to remove unbound substances, biotinylated detection antibodies are added and incubated. After washing to remove unbound biotinylated antibodies, streptavidin-HRP labeled with horseradish peroxidase is added. After washing again, a signal enhancer is added and incubated. After washing to remove unbound substances, Streptavidin-HRP is added once more. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of IL-17A in the samples. A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).


 

References (0)

No References

Bought notes(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.