TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Human Endothelin 1/ET-1 Competitive ELISA Kit
Sunlong Medical™ Human Endothelin 1/ET-1 Competitive ELISA Kit
EDN1 elisa kit | endothelin 1 elisa kit | ARCND3 | endothelin-1 | ET1 | HDLCQ7 | PPET1 | preproendothelin-1 | QME
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Cat NO.:
EL0080Hu
Product:
Sunlong Medical™ Human Endothelin 1/ET-1 Competitive ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
90% - 108%
Mean Spike Recovery:
0.98
CV of Intra plate:
3.1% - 6.2%
CV of Inter plate:
4.2%-7.0%
NCBI_Gene:
1906
UniProtKB:
P05305

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-ET-1 monoclonal antibody
Human ET-1 freeze-dried standard
Angiotensinogen/AGT/ SerpinA8 detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes a solid-phase competitive enzyme-linked immunosorbent assay (ELISA) technique. Specific monoclonal antibodies against human ET-1 are precoated on a high-affinity ELISA plate. Biotinylated ET-1 and unlabeled ET-1 or samples are added into the wells of the ELISA plate, competing to bind to the limited binding sites on the coated antibody. After washing to remove unbound substances, HRP-labeled streptavidin is added. After washing again, TMB chromogenic substrate is added for color development while avoiding light. The intensity of the color reaction is inversely proportional to the concentration of ET-1 in the sample. The reaction is terminated by adding a stop solution, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

Partial purchase records(bought amounts latest8)

UsernameQuantitybought time
Ol***12024-08-14
Ge***22024-08-10
Ga***32024-07-22
Ra***12024-07-09
Al***32024-06-27
Total 8 records, divided into2 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.