TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Human ACE2 ELISA Kit
Sunlong Medical™ Human ACE2 ELISA Kit
ACE2 elisa kit | angiotensin converting enzyme 2 elisa kit | ACE-related carboxypeptidase | ACEH | angiotensin I converting enzyme peptidyl-dipeptidase A 2 | angiotensin I converting enzyme 2 | angiotensin-converting enzyme 2 | angiotensin-converting en
Total
(Vip priceV)
Regular members: $455.2
  • Save more [Favourable] 45% Discount
  • NO.:EL0064Hu
    Species:Human
    Assay range:0.31ng/mL-20ng/mL
    Sensitivity:29.60 pg/mL
    Sample Volume:50 μL
    Assay type:Sandwich Method
    Validity:Two Years
  • Goods click count:133
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
View History [Clear]

Details

Cat NO.:
EL0064Hu
Product:
Sunlong Medical™ Human ACE2 ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
98% - 121%
Mean Spike Recovery:
1.08
CV of Intra plate:
3.1% - 4.9%
CV of Inter plate:
3.6%-4.2%
NCBI_Gene:
59272
UniProtKB:
Q9BYF1

 

PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-ACE2 monoclonal antibody
Human ACE2 freeze-dried standard
ACE2 detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-human ACE2 antibodies are precoated on a high-affinity ELISA plate.Standards and test samples are added to the wells of the ELISA plate. After incubation, the ACE2 present in the samples binds to the solid-phase antibodies. After washing to remove unbound substances, biotinylated detection antibodies are added and incubated. After washing to remove unbound biotinylated antibodies, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of ACE2 in the samples.A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

Bought notes(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.