Sunlong Medical™ Mouse sL-selectin/CD62L ELISA Kit
Sunlong Medical™ Mouse sL-selectin/CD62L ELISA Kit
SELL elisa kit | selectin L elisa kit | AI528707 | CD62L | expressed sequence AI528707 | L-selectin | LECAM-1 | Lnhr | Ly-22 | Ly-m22 | Lyam-1 | Lyam1 | lymph node homing receptor | lymphocyte adhesion molecule 1 | lymphocyte antigen 22 | lymphocyte antig
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Cat NO.:
EL0022Mo
Product:
Sunlong Medical™ Mouse sL-selectin/CD62L ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
84% - 106%
Mean Spike Recovery:
0.95
CV of Intra plate:
3.7% - 4.8%
CV of Inter plate:
2.6%-5.0%
NCBI_Gene:
20343
UniProtKB:
P18337

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-sL-selectin monoclonal antibody
Mouse sL-selectin freeze-dried standard
sL-selectin detect Antibody
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-鼠BAFF antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and the detection antibody labeled with horseradish peroxidase are added to the wells of the ELISA plate. After incubation, CD30 present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of CD30 in the samples. A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-632 nm).

Partial purchase records(bought amounts latest8)

UsernameQuantitybought time
Ow***32024-09-07
Na***22024-08-31
Be***12024-07-05
Ow***32024-06-06
Ev***12024-05-17
Total 8 records, divided into2 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.