TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Mouse HGF ELISA Kit
Sunlong Medical™ Mouse HGF ELISA Kit
SOS1 elisa kit | SOS Ras/Rac guanine nucleotide exchange factor 1 elisa kit | AI573415 | expressed sequence AI573415 | Sfpd | Sftp4 | SP-D | surfactant-associated protein 4
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Citations

Cat NO.:
EL0008Mo
Product:
Sunlong Medical™ Mouse HGF ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
91% - 118%
Mean Spike Recovery:
1.03
CV of Intra plate:
3.4% - 4.2%
CV of Inter plate:
3.2% - 4.3%
NCBI_Gene:
20662
UniProtKB:
Q62245

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-Mouse HGF monoclonal antibody
Mouse HGF freeze-dried standard
Mouse HGF detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-mouse HGF antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and the detection antibody labeled with horseradish peroxidase are added to the wells of the ELISA plate. After incubation, HGF present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of HGF in the samples.A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 1. Liposome-anchored mesenchymal stem cells for radiation pneumonia/fibrosis treatment

BIOMATERIALS 2023-06-14

References (0)

No References

Bought notes(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.