TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Human BID ELISA Kit
Sunlong Medical™ Human BID ELISA Kit
BID elisa kit | BH3 interacting domain death agonist elisa kit | apoptic death agonist | BH3 interacting domain death agonist Si6 isoform | BH3-interacting domain death agonist | BID isoform ES1b | BID isoform L2 | BID isoform Si6 | desmocollin type 4
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

SAMPLE TYPE Serum, plasma, cell culture supernatant, and other biological samples
SAMPLE VOLUME 5 μL
SENSITIVITY 0.51 pg/mL
RANGE 15.63 pg/mL – 1000 pg/mL
ASSAY TIME 3.5 h
RECOVERY 93% – 109%
AVERAGE RECOVERY 1.02
INTRA PRECISION 2.3% – 3.0%
INTER-PRECISION 1.7% – 2.2%
PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with specific anti-human BID antibody
Human BID freeze-dried standard
Streptavidin-HRP labeled human BID detect Antibody
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
Standard Diluent
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-human BID antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and the detection antibody labeled with horseradish peroxidase are added to the wells of the ELISA plate. After incubation, BID present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing, the TMB chromogenic substrate is added, and color development is carried out while avoiding light. The intensity of the color reaction is directly proportional to the concentration of BID in the samples. A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

Partial purchase records(bought amounts latest17)

UsernameQuantitybought time
Le***22024-08-05
Fe***12024-08-03
Os***12024-07-22
Pa***12024-06-30
Pa***22024-06-01
Total 17 records, divided into4 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.