TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Mouse myeloperoxidase/MPO ELISA Kit
Sunlong Medical™ Mouse myeloperoxidase/MPO ELISA Kit
MPO elisa kit | myeloperoxidase elisa kit
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Citations

Cat NO.:
EL0091Mo
Product:
Sunlong Medical™ Mouse myeloperoxidase/MPO ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
91% - 107%
Mean Spike Recovery:
0.99
CV of Intra plate:
3.8 % - 5.4 %
CV of Inter plate:
3.0 % - 4.1 %
NCBI_Gene:
17523
UniProtKB:
P11247
PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-MPO monoclonal antibody
Mouse MPO freeze-dried standard
MPO detect Antibody
HRP-labeled streptavidin
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-mouse MPO antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, MPO present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing to remove unbound substances, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, the TMB chromogenic substrate is added, and color development is carried out while avoiding light. The intensity of the color reaction is directly proportional to the concentration of MPO in the samples. A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

 

 
 
 
 
 
 
 
 
 
 

Partial purchase records(bought amounts latest2)

UsernameQuantitybought time
Is***22024-08-17
Et***12024-07-08
Total 2 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.