TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Mouse IL-17F ELISA Kit
Sunlong Medical™ Mouse IL-17F ELISA Kit
IL17F elisa kit | interleukin 17F elisa kit | C87042 | expressed sequence C87042
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Citations

Cat NO.:
EL0069Mo
Product:
Sunlong Medical™ Mouse IL-17F ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
95% - 112%
Mean Spike Recovery:
1.06
CV of Intra plate:
2.9 % - 4.1 %
CV of Inter plate:
3.3 % - 4.1 %
NCBI_Gene:
257630
UniProtKB:
Q7TNI7

 

PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-IL-17F monoclonal antibody
Mouse IL-17F freeze-dried standard
IL-17F detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-mouse IL-17F antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, IL-17F present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing to remove unbound substances, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of IL-17F in the samples. A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

 ILC2 regulates hyperoxia-induced lung injury via an enhanced Th17 cell response in the BPD mouse model

Partial purchase records(bought amounts latest17)

UsernameQuantitybought time
Ja***32024-08-31
Pa***12024-08-21
Mi***32024-08-17
Is***12024-08-17
Re***22024-07-06
Total 17 records, divided into4 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.