TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Human KGF/FGF-7 ELISA Kit
Sunlong Medical™ Human KGF/FGF-7 ELISA Kit
FGF7 elisa kit | fibroblast growth factor 7 elisa kit | FGF-7 | HBGF-7 | heparin-binding growth factor 7 | keratinocyte growth factor | KGF
Total
(Vip priceV)
Regular members: $455.2
View History [Clear]

Details

Cat NO.:
EL0122Hu
Product:
Sunlong Medical™ Human KGF/FGF-7 ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
80% - 120%
Mean Spike Recovery:
0.96
CV of Intra plate:
3.6% - 4.4%
CV of Inter plate:
2.1% - 3.6%
NCBI_Gene:
2252
UniProtKB:
P21781
PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-KGF monoclonal antibody
Human KGF freeze-dried standard
KGF detect Antibody
Standard Diluent
HRP-labeled streptavidin
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-human KGF antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, KGF present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing to remove unbound substances, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, the TMB chromogenic substrate is added, and color development is carried out while avoiding light. The intensity of the color reaction is directly proportional to the concentration of KGF in the samples. A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

  

 

Partial purchase records(bought amounts latest24)

UsernameQuantitybought time
So***22024-08-30
Al***32024-08-29
Al***12024-08-25
No***32024-08-01
Da***12024-07-30
Total 24 records, divided into5 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.