Cat NO.:
EL0245Hu
Product:
Sunlong Medical™ Human Angiopoietin-1/ANG-1 ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cellular supernatant
Spike Recovery Range:
80% - 110%
Mean Spike Recovery:
0.94
CV of Intra plate:
3.3% - 5.4%
CV of Inter plate:
5.0% - 8.2%
NCBI_Gene:
284
UniProtKB:
Q15389

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-Angipoietin-1/ANG-1 monoclonal antibody
Human Angipoietin-1/ANG-1 freeze-dried standard
Angipoietin-1/ANG-1 detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-human ANG-1 antibodies are precoated on a high-affinity ELISA plate.Standards and test samples are added to the wells of the ELISA plate. After incubation, the ANG-1 present in the samples binds to the solid-phase antibodies. After washing to remove unbound substances, biotinylated detection antibodies are added and incubated. After washing to remove unbound biotinylated antibodies, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of ANG-1 in the samples.A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 System Analysis Based on Lipid-Metabolism-Related Genes Identifies AGT as a Novel Therapy Target for Gastric Cancer with Neoadjuvant Chemotherapy

  • Impact factors: 6.525
  • Publication: Pharmaceutics
  • Author:Le Zhu, Ming Ma, Lumin Zhang, Shun Wang, Yu Guo, Xinxin Ling, Hanchao Lin, Nannan Lai, Shengli Lin, Ling Du, Qiongzhu Dong
  • DOI citation-doi:10.3390/pharmaceutics15030810
  • Date:2023-03-02

 

Partial purchase records(bought amounts latest22)

UsernameQuantitybought time
Th***22024-09-11
Zo***12024-09-03
Le***32024-08-13
Na***12024-07-29
Pe***12024-07-16
Total 22 records, divided into5 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.